A myocardial reorientation method based on feature point detection for quantitative analysis of PET myocardial perfusion imaging

Fei Shang, Li Huo, Tan Gong, Peipei Wang, Ximin Shi, Xiaoying Tang, Shuai Liu*

*此作品的通讯作者

科研成果: 期刊稿件文章同行评审

摘要

Objective: Reorienting cardiac positron emission tomography (PET) images to the transaxial plane is essential for cardiac PET image analysis. This study aims to design a convolutional neural network (CNN) for automatic reorientation and evaluate its generalizability. Methods: An artificial intelligence (AI) method integrating U-Net and the differentiable spatial to numeric transform module (DSNT-U) was proposed to automatically position three feature points (Papex, Pbase, and PRV), with these three points manually located by an experienced radiologist as the reference standard (RS). A second radiologist performed manual location for reproducibility evaluation. The DSNT-U, initially trained and tested on a [11C]acetate dataset (training/testing: 40/17), was further compared with a CNN-spatial transformer network (CNN-STN). The network fine-tuned with 4 subjects was tested on a [13N]ammonia dataset (n = 30). The performance of the DSNT-U was evaluated in terms of coordinates, volume, and quantitative indexes (pharmacokinetic parameters and total perfusion deficit). Results: The proposed DSNT-U successfully achieved automatic myocardial reorientation for both [11C]acetate and [13N]ammonia datasets. For the former dataset, the intraclass correlation coefficients (ICCs) between the coordinates predicted by the DSNT-U and the RS exceeded 0.876. The average normalized mean squared error (NMSE) between the short-axis (SA) images obtained through DSNT-U-based reorientation and the reference SA images was 0.051 ± 0.043. For pharmacokinetic parameters, the R² between the DSNT-U and the RS was larger than 0.968. Compared with the CNN-STN, the DSNT-U demonstrated a higher ICC between the estimated rigid transformation parameters and the RS. After fine-tuning on the [13N]ammonia dataset, the average NMSE between the SA images reoriented by the DSNT-U and the reference SA images was 0.056 ± 0.046. The ICC between the total perfusion deficit (TPD) values computed from DSNT-U-derived images and the reference values was 0.981. Furthermore, no significant differences were observed in the performance of the DSNT-U prediction among subjects with different genders or varying myocardial perfusion defect (MPD) statuses. Conclusions: The proposed DSNT-U can accurately position Papex, Pbase, and PRV on the [11C]acetate dataset. After fine-tuning, the positioning model can be applied to the [13N]ammonia perfusion dataset, demonstrating good generalization performance. This method can adapt to data of different genders (with or without MPD) and different tracers, displaying the potential to replace manual operations.

源语言英语
文章编号108837
期刊Computer Methods and Programs in Biomedicine
268
DOI
出版状态已出版 - 8月 2025
已对外发布

指纹

探究 'A myocardial reorientation method based on feature point detection for quantitative analysis of PET myocardial perfusion imaging' 的科研主题。它们共同构成独一无二的指纹。

引用此